NVELOPE® NV93 System
Suitable for mechanical concealed / secret fixing of various cladding materials including fibre cement, GRC, ceramic, stone and many more.
Want to Know More?
About
- NV93 is the Nvelope system for mechanical concealed / secret fix cladding applications.
- Secured using hangers and undercut, stud anchors or screws to provide a concealed rear fixing.
- Horizontal carrier profiles are fixed to our vertical NV9 omega top hat profiles. Rainscreen panels are hung from and secured to the NV3 horizontal profiles with adjustable hangers.
- Ideal for shallow cladding zones, with a fixed cavity zone of just 50mm.
- Nvelope rail and associated fixing spacing is determined by cladding options such as the dimensions and weight of the facade cladding, local wind loads, cladding zone, and substrate.
- This simplistic system does not allow for level and adjustment between the substrate and the front of the façade without the use of packing.
Applications
NV93 is suitable for concealed / secret fix cladding applications – mechanical elements fix to the following substrates:
- Fibre cement Panels
- Glass reinforced concrete (GRC)
- Ceramic
- Stone
- Stainless Steel
- High Pressure Laminate (HPL)
Features
- Manufactured from extruded aluminium alloys conforming to AS/NZS 1866:1997 (material) and EN 755 production standards.
- Non-Combustible to AS1530.1
- Suitable in high corrosive environments C4 and C5.
- Engineered to Australian Standards.
Documentation
Need more system info? Download our detailed system drawings, installation guides and associated data sheets.
Download NV93 DocumentationOrder AutoCAD DrawingsMaterial
The selection of materials to use in the construction of a subframe system within a rainscreen façade is of paramount importance. Material choice can also affect the thermal performance of the overall rainscreen in addition to engineering assurance.
- Aluminium is inherently corrosion resistant however this can be complemented and further improved by additional treatment including anodising and powder coating.
- All NVELOPE systems only use the superior 6005 T5 alloy, which provides superior strength and performance over and above other commonly used aluminium.
Standards
- AS/NZS 1170.0 Structural design actions Part 0: General principles
- AS/NZS 1664.1 Aluminium structures Part 1: Limit state design
- AS/NZS 1866 Aluminium and aluminium alloys – Extruded rod, bar, solid and hollow shapes
- AS1530.1 Methods for fire tests on building materials, components, and structures Combustibility test for materials